Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.11861/7512
Title: Non-invasive assessment of liver fibrosis with transient elastography (FibroScan®): Applying the cut-offs of M probe to XL probe
Authors: Wong, Grace Lai-Hung 
Vergniol, Julien 
Lo, Peter 
Wong, Vincent Wai-Sun 
Foucher, Juliette 
Le Bail, Brigitte 
Choi, Paul Cheung-Lung 
Chermak, Faiza 
Prof. LEUNG Kwong Sak 
Merrouche, Wassil 
Chan, Henry Lik-Yuen 
de Lédinghen, Victor 
Issue Date: 2013
Publisher: Fundacion Clinica Medica Sur
Source: Annals of Hepatology , 12(4), pp. 402-412
Journal: Annals of Hepatology 
Abstract: Background and rationale for the study. Limited studies have aimed to define the cut-offs of XL probe (XL cut-offs) for different stages of liver fibrosis, whereas those of M probe (M cut-offs) may not be applicable to XL probe. We aimed to derive appropriate XL cut-offs in overweight patients. Patients with liver stiffness measurement (LSM) by both probes were recruited. XL cut-offs probe for corresponding M cut-offs were derived from an exploratory cohort, and subsequently validated in a subgroup patients also underwent liver biopsy. The diagnostic accuracy of XL cut-offs to diagnose advanced fibrosis was evaluated. Results. Total 517 patients (63% male, mean age 58) who had reliable LSM by both probes were included in the exploratory cohort. There was a strong correlation between the LSM by M probe (LSM-M) and LSM by XL probe (LSM-XL) (r2 = 0.89, p < 0.001). A decision tree using LSM-XL was learnt to predict the 3 categories of LSM-M (< 6.0kPa, 6.0-11.9kPa and ≥ 12.0kPa), and XL cut-offs at 4.8kPa and 10.7kPa were identified. These cut-offs were subsequently validated in a cohort of 147 patients who underwent liver biopsy. The overall accuracy was 89% among 62 patients whose LSM-XL < 4.8kPa or ≥ 10.7kPa. These cut-offs would have avoided under-staging of fibrosis among patients with body mass index (BMI) > 25-30 kg/m2 but not > 30 kg/m2. Conclusions. XL cut-offs at 4.8kPa and 10.7kPa were the best estimates of 6.0kPa and 12.0kPa of M probe for patients with BMI > 25-30 kg/m2. Patients with BMI > 30 kg/m2 might use M probe cut-offs for XL probe.
Type: Peer Reviewed Journal Article
URI: http://hdl.handle.net/20.500.11861/7512
ISSN: 16652681
DOI: 10.1016/s1665-2681(19)31341-9
Appears in Collections:Publication

Show full item record

SCOPUSTM   
Citations

19
checked on Jan 3, 2024

Page view(s)

20
checked on Jan 3, 2024

Google ScholarTM

Impact Indices

Altmetric

PlumX

Metrics


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.