Lau, L. N.L. N.LauKan, C. W.C. W.KanLam, H. L. I.H. L. I.LamMurrells, C. M.C. M.MurrellsYuen, C. W. M.C. W. M.YuenProf. LAU Kung Wong, NickNickProf. LAU Kung Wong2023-05-252023-05-252011Textile Asia, 2011, XLII(7), 34-37.0049-3554http://hdl.handle.net/20.500.11861/7879This study found that the values of colour standard samples measured after conditioning with Setting 1 have a very strong positive correlation with those measured after conditioning with Setting 2 by the same spectrophotometer. Also, the values of colour standard samples measured by spectrophotometer Datacolor 600 have a very strong positive correlation with those measured by spectrophotometer SF600 plus CT after same sample conditioning setting.enBusiness and International ManagementChemistry (Miscellaneous)General Business Management and AccountingIndustrial and Manufacturing EngineeringEffect of Sample Conditioning on Instrumental Colour Measurement on Nylon Interlock Fabric.Peer Reviewed Journal Article